Fujitsu F2 MC-16 Computer Accessories User Manual


 
98
CHAPTER 2 DEPENDENCE FUNCTIONS
[Setup Examples]
- Terminate sequencer when event 1 occurs.
>SET SEQUENCE/EVENT 1,1,J=0
- Terminate sequencer when event 2 occurs 16 times.
>SET SEQUENCE/EVENT 1,2,16,J=0
- Terminate sequencer when event 2 occurs after event 1 occurred. However, do not terminate sequencer
if event 3 occurs between event 1 and event 2.
>SET SEQUENCE/EVENT 1,1,J=2
>SET SEQUENCE/EVENT 2,2,J=0
>SET SEQUENCE/EVENT 2,3,J=1
- Terminate sequencer if and when event 2 occurs less than 300 μs after event 1 occurred.
>SET SEQUENCE/EVENT 1,1,J=2
>SET SEQUENCE/EVENT 2,2,J=0
>SET SEQUENCE/TIMER 2,300,J=1
>SHOW SEQUENCE
Sequencer Enable
level1 level2 level3 level4 level5 level6 level7 level8
1 |1|->2 | | | | | | | | | | | | | |
2 | | |2|->end | | | | | | | | | | | |
3 | | | | | | | | | | | | | | | |
4 | | | | | | | | | | | | | | | |
5 | | | | | | | | | | | | | | | |
6 | | | | | | | | | | | | | | | |
7 | | | | | | | | | | | | | | | |
8 | | | | | | | | | | | | | | | |
T | | |T|->1 | | | | | | | | | | | |
Latch 1 ( -> ) = Latch 2 ( -> ) =
>SHOW SEQUENCE 2
level no. = 2
event pass-count
trace-cnt1
jmp-level1
2 1 enable end
timer 00:00:000:300:000 enable 1
Indicates
move to level
2 when event
1 occurs at
level 1
Indicate s terminating
sequencer when event 2
occurs at level 2.
Indicates move to level 1 if and
when 300
μ
s passed before
event 2 occurs at level 2