Fujitsu F2 MC-16 Computer Accessories User Manual


 
245
CHAPTER 2 DEPENDENCE FUNCTIONS
2.5.4.2 Data Break
It is a function to abort the program execution when the data access (read and write) is
done to a specified address.
Data Break
It is a function to abort the program execution when the data access (read and write) is done to a specified
address.
When a break occurs due to a data break, the following message is displayed on the Status Bar.
Break at Address by databreak at Access address
Setting Method
The data break is controlled by the following method.
Command
- SET DATABREAK
Refer to "3.9 SET DATABREAK (type 1)" in "SOFTUNE Workbench Command Reference Manual".
Dialog
- Breakpoint Set Dialog [Data] tab
Refer to "4.6.4 Breakpoint" in "SOFTUNE Workbench Operation Manual".
Notes:
Due to combination use with the sequencer or trace trigger, the maximum setting number varies.
Word access from an odd address is performed using the byte access for twice (in terms of bus
access). Note that this is the reason why even when word access from an odd address is specified,
there will not be any hits.