198
CHAPTER 2 DEPENDENCE FUNCTIONS
For details about settings of the RAM Checker viewer, refer to Section "3.21 RAM Checker Window" of
"SOFTUNE Workbench Operation Manual". and "4.47 SET RAMCHECK" to "4.51 DISABLE
RAMCHECK" of "SOFTUNE Workbench Command Reference Manual".
Note:
Execution state for MCU such as stop mode or sleep mode cannot be displayed at status bar during
logging.
■ About Log File
Following restrictions are made for the size of log file to be created depending on file system where log file is
stored.
FAT:Up to 2GB
FAT32: Up to 4GB
NTFS: No limit.
Others: No limit
If the file system is FAT, FAT32, file name will be changed and continue logging when the size of file is
exceeded limitation.
Note:
If a file is already existed, log file will be overwritten
Example of an operation
If the size of file is exceeded it's limitation, log file will be created as
filename.srl --> filename#1.srl
If the size gets exceeded the limitation again, log will be shown and changes as follows.
filename#1.srl --> filename#2.srl
•
•
filename#N-1.srl --> filename#N.srl
Notes:
• Log files should only be saved to built-in HDD only. If network, external HDD or external disk (CD,
DVD, MO etc) are used as destination for saving files, files will not be saved.
• More than 500MB memory is required for disk to save log file of RAM checker. If the capacity of