Fujitsu F2 MC-16 Computer Accessories User Manual


 
73
CHAPTER 2 DEPENDENCE FUNCTIONS
2.2.1.5 Timer Minimum Measurement Unit
The timer minimum measurement unit affects the sequencer, the emulation timer and the
performance measurement timer.
Setting Timer Minimum Measurement Unit
Choose either 1 μs or 100 ns as the timer minimum measurement unit for the emulator for measuring time.
The minimum measurement unit for the following timers is changed depending on this setup.
Timer values of sequencer (timer conditions at each level)
Emulation timer
Performance measurement timer
Table 2.2-3 shows the maximum measurement time length of each timer when 1 μs or 100 ns is selected as
the minimum measurement unit.
When the minimum measurement unit is changed, the measurement values of each timer are cleared as well.
The default setting is 1 μs.
Use the following commands to control timers.
SET TIMERSCALE : Sets minimum measurement unit for timers
SHOW TIMERSCALE : Displays status of minimum measurement unit setting for timers
[Example]
>SET TIMERSCALE/100N
>SHOW TIMERSCALE
Timer scale : 100ns
>
Table 2.2-3 Maximum Measurement Time Length of Each Timer
1 μs selected 100 ns selected
Sequencer timer About 16 seconds About 1.6 seconds
Emulation timer About 70 minutes About 7 minutes
Performance measurement timer About 70 minutes About 7 minutes