Fujitsu F2 MC-16 Computer Accessories User Manual


 
187
CHAPTER 2 DEPENDENCE FUNCTIONS
2.3.7.2 Display Performance Measurement Data
Display the measured time and measuring count by using the SHOW PERFORMANCE
command.
Displaying Measured Time
To display the time measured, specify the starting event number or the ending event number.
>SHOW PERFORMANCE/TIME 1,9000,18999,1000
event = 1 -> 2 time (
µ
s) | count
min time = 11637.0 -----------------------------+---------
max time = 17745.0 0.0 - 8999.0 | 0
avr time = 14538.0 9000.0 - 9999.0 | 0
10000.0 - 10999.0 | 0
11000.0 - 11999.0 | 2
12000.0 - 12999.0 | 19
13000.0 - 13999.0 | 52
14000.0 - 14999.0 | 283
15000.0 - 15999.0 | 92
16000.0 - 16999.0 | 3
17000.0 - 17999.0 | 1
18000.0 - 18999.0 | 0
19000.0 - | 0
-----------------------------+---------
total | 452
Minimum
execution time
Event number
Maximum
execution time
Average
execution time
Count of measuring within given time interval
Total measuring count
>SHOW PERFORMANCE/TIME 1,13000,16999,500
event = 1 -> 2 time (µs) | count
min time = 11637.0 -----------------------------+---------
max time = 17745.0 0.0 - 12999.0 | 21
avr time = 14538.0 13000.0 - 13499.0 | 13
13500.0 - 13999.0 | 39
14000.0 - 14499.0 | 121
14500.0 - 14999.0 | 162
15000.0 - 15499.0 | 76
15500.0 - 15999.0 | 16
16000.0 - 16499.0 | 2
16500.0 - 16999.0 | 1
17000.0 - 17499.0 | 1
-----------------------------+---------
total | 452
Upper time limit for display
Lower time limit for display