The sequence event is setting by the following command.
SET SEQUENCE :Sets sequence event
SHOW SEQUENCE :Displays sequence event status
CANCEL SEQUENCE :Deletes event
Notes:
In instruction execution (/CODE), an event trigger is generated only when an instruction is executed.
This cannot be specified concurrently with other status (/READ or /WRITE).
In the case of data event, word access from an odd address (in terms of bus access) is performed
using a byte access for twice . Note that this is the reason why even when word access from an
odd address is specified there is nothing found.