Genicom GEK 00031B Printer User Manual


 
Chapter 5. Proprinter Emulation GEK-00029B
114
ESC 3 n Set Graphics Line Spacing:
Sets the line spacing to n units of 1/216
inch. This allows for line spacing in .0046 inch increments to 1.18
inches (255/216). The value of n/216 is rounded up to the next
1/144 inch.
n = 1 through 255
Example: ESC 3 27 Sets the line spacing to 1/8 inch, or
27/216.
Decimal: 27 51 <n>
Hex: 1B 33 <n>
BASIC: CHR$(27);"3<n>";
ESC 4 Set Top of Form:
Sets current paper position as top of form.
Decimal: 27 52
Hex: 1B 34
BASIC: CHR$(27);"4";
ESC 5 n Automatic Line Feed:
Printer automatically does a line feed after
receiving a carriage return.
n = 0, disabled
n = 1, enabled
Decimal: 27 53 <n>
Hex: 1B 35 <n>
BASIC: CHR$(27);"5<n>";
ESC 6 Select Character Set 2:
All characters (printable and control codes)
received after this command are selected from character set 2. A
reset, initialization, or ESC 7 resets to character set 1.
Decimal: 27 54
Hex: 1B 36
BASIC: CHR$(27);"6";
ESC 7 Select Character Set 1:
All characters (printable and control codes)
received after this command are selected from character set 1. Also,
see ESC 6 above.
Decimal: 27 55
Hex: 1B 37
BASIC: CHR$(27):"7";
ESC A n Stores n/72-inch Line Spacing:
The text line spacing is stored,
although not set for use, to the value n in units of 1/72 inch. An ESC
2 must be sent to start this line spacing. Valid parameter values are
1 through 85.
Decimal: 27 65 <n>
Hex: 1B 41 <n>
BASIC: CHR$(27);"A<n>";