Genicom GEK 00031B Printer User Manual


 
Chapter 8. PPL3 Plus Emulation GEK-00029B
260
DECGRI (!) Graphics Repeat Introducer:
Repeats the following sixel a specified
number of times.
Format
! Pn
Description
The printer repeats the sixel following the DECGRI sequence Pn
times.
The repeat function supports parameters large enough to cover the
largest print line at the smallest grid size, up to 32K.
The following examples illustrate repeat sequences:
! 1 0 ? Repeats 10 graphics spaces
! 6 @ Repeats 6 patterns of top dot
Error Handling
A repeat count of zero or omitted is treated as a repeat count of one.
Values that exceed the maximum value are treated as the maximum
value. If no sixel printable character follows the repeat count, the
repeat count is ignored.
If a graphics control code is received within a DECGRI sequence, the
repeat sequence is ignored. This includes sequences in the range 21
to 2F, 3A, and 3C to 3E. If multiple parameters are received
(separated by semicolons), the printer uses the first parameter and
ignores the rest.
5000 Series PPLIII
Ps1
Aspect
Ratio
Appr. Horz.
Grid Size
True Vert.
Grid Size
Appr. Horz.
Grid Size
True Vert.
Grid Size
0 200:100 50 100 144 72
1 200:100 50 100 144 72
2 450:100 22 100 324 72
3 300:100 33 100 216 72
4 250:100 40 100 180 72
5 183:100 54 100 132 72
6 150:100 66 100 108 72
7 130:100 77 100 94 72
8 112:100 89 100 81 72
9 100:100 100 100 72 72
>9 200:100 50 100 144 72