Genicom GEK 00031B Printer User Manual


 
GEK-00029A 5000 Series Programmer’s Manual
187
DECSTR Soft Terminal Reset:
Resets the value or state of several operating
features. After receiving a DECSTR, the printer positions itself at the
next Top Of Form then resets the value or state of several operating
features.
General Command Syntax
ESC [ ! p
Decimal: 27 71 17 84
Hex: 1B 5B 21 70
BASIC: CHR$(27);"[";"!p";
Selectable Parameter Reset Condition
Printing Status On-line
Horizontal Pitch 10 characters per inch
Vertical Pitch 6 lines per inch
Font Data Processing
Forms Length 66 lines (11 inches)
Active position Column 1 on the current line
Top Margin Line 1
Bottom Margin Line 66
Left Margin Column 1
Right Margin Column 136
Underlining Disabled
Bolding Disabled
Italics Disabled
Double Underline Disabled
Overline Disabled
Expansion No character expansion
GL Character Set US ASCII
GR Character Set Digital Supplemental
G0 US ASCII
G1 VT100 Graphic Character Set
G2 Digital Supplemental
G3 US ASCII
Autowrap Disabled
Line Feed/New Line Mode Reset
Horizontal Tabs Every 8 columns (9,17 …)
Unsolicited Reports Disabled
Super/Subscripts Disabled
Carriage Return/New line Reset
Vertical Tabs Every line (1-66)
NOTE
This sequence and the RIS reset sequence have the same
function.