Genicom GEK 00031B Printer User Manual


 
GEK-00029B 5000 Series Programmer’s Manual
255
Control
Function
Type Margin effect Parameter Used Flags
Partial Line
Up
Special Can go up to one PLU
position above top margin
All
(Maximum
PLU/PLD count
value is 255)
Increments the PLU/PLD count
Reverse
Index
Relative Can go up to top margin All Clears PLU/PLD count and
Superscript/Subscript count.
Resulting vertical position
above top margin Sets FCF.
Vertical
Position
Absolute
Absolute Maximum vertical movement
possible is up to bottom
margin. Resulting vertical
position more than bottom
margin will set the active
vertical position to bottom
margin
All Clears PLU/PLD count and
Superscript/ Subscript count..
In RESET mode command sets
the FCF flag.
Vertical
Position
Backward
Relative Can go up to top margin. All Clears PLU/PLD count and
Superscript/Subscript count.
Sets the FCF if the resulting
vertical position is above top
margin.
Vertical
Position
Relative
Relative Performs the FF if resulting
vertical position is below
bottom margin.
All Clears PLU/PLD count and
Superscript/Subscript count.
In RESET mode command sets
the FCF flag.
Vertical Tab Absolute If there is no tabs in the tab
table or no valid tab between
the current position and BM
then VT brings the cursor to
bottom margin (BM).
All Clears PLU/PLD count and
Superscript/Subscript count.
Sets the FCF
Bounds
Page Home Line is same as Top Margin Line
Page End Line is same as Bottom Margin Line
Line Home Position is same as Left Margin Position
Line End Position is same as Right Margin Position