Hitachi SJ700-2 Power Supply User Manual


 
Contents
x
4.2.32 Overload restriction/overload notice (b021 to b026, C001 to C008, C021 to C026,
C040, C041, C111) ······································································································4 - 40
4.2.33 Overcurrent restraint (b027) ························································································4 - 41
4.2.34 Overvoltage restraint during deceleration (b130 to b132) ···········································4 - 42
4.2.35 Start frequency setting (b082)······················································································4 - 43
4.2.36 Reduced voltage start function (b036, b082)·······························································4 - 43
4.2.37 Dynamic braking (BRD) function (b090, b095, b096)··················································4 - 44
4.2.38 Cooling-fan operation setting (b092) ···········································································4 - 44
4.2.39 Intelligent input terminal setting (SET, SET3) (C001 to C008) ····································4 - 45
4.2.40 Input terminal a/b (NO/NC) selection (C011 to C018, C019)·······································4 - 46
4.2.41 Multispeed select setting (CF1 to CF4 and SF1 to SF7) (A019, A020 to A035,
C001 toC008)···············································································································4 - 46
4.2.42 Jogging (JG) command setting (A038, A039, C001 to C008) ·····································4 - 48
4.2.43 2nd/3rd motor control function (SET and SET3)··························································4 - 49
4.2.44 Software lock (SFT) function (b031, C001 to C008)····················································4 - 50
4.2.45 Forcible-operation from digital operation (OPE) function (A001, A002,
C001 to C008)··············································································································4 - 50
4.2.46 Forcible-operation from terminal (F-TM) function (A001, A002, C001 to C008)··········4 - 50
4.2.47 Free-run stop (FRS) function (b088, b033, b007, b028 to b030, C001 to C008)········4 - 51
4.2.48 Commercial power source switching (CS) function (b003, b007, C001 to C008) ·······4 - 52
4.2.49 Reset (RS) function (b003, b007, C102, C103, C001 to C008) ··································4 - 53
4.2.50 Unattended start protection (USP) function (C001 to C008)·······································4 - 55
4.2.51 Remote control function (UP and DWN) (C101, C001 to C008) ·································4 - 55
4.2.52 External trip (EXT) function (C001 to C008)································································4 - 56
4.2.53 3-wire interface operation function (STA, STP, and F/R) (C001 to C008) ···················4 - 56
4.2.54 Control gain switching function (CAS) (A044, C001 to C008, H005, H050 to H052,
H070 to H072)··············································································································4 - 57
4.2.55 P/PI switching function (PPI) (A044, C001 to C008, H005, H050 to H052,
H070 to H072)··············································································································4 - 57
4.2.56 Analog command holding function (AHD) (C001 to C008)··········································4 - 58
4.2.57 Intelligent pulse counter (PCNT and PCC)··································································4 - 58
4.2.56 Intelligent output terminal setting (C021 to C026) ·······················································4 - 59
4.2.57 Intelligent output terminal a/b (NO/NC) selection (C031 to C036) ······························4 - 60
4.2.58 Running signal (RUN) (C021 to C025) ········································································4 - 61
4.2.59 Frequency arrival signals (FA1, FA2, FA3, FA4, and FA5) (C021 to C025, C042,
C043, C045, C046)······································································································4 - 61
4.2.60 Running time over and power-on time over signals (RNT and ONT)
(b034, C021to C026, d016, d017) ···············································································4 - 63
4.2.61 0 Hz speed detection signal (ZS) (A044, C021 to C025, C063)··································4 - 63
4.2.62 Over-torque signal (OTQ) (A044, C021 to C025, C055 to C058) ·······························4 - 64
4.2.63 Alarm code output function (AC0 to AC3) (C021 to C025, C062) ·······························4 - 64
4.2.64 Logical output signal operation function (LOG1 to LOG6) (C021 to C026,
C142 to C159)··············································································································4 - 65
4.2.65 Capacitor life warning signal (WAC) (C021 to C026) ··················································4 - 66
4.2.66 Communication line disconnection signal (NDc) (C021 to C026, C077)·····················4 - 66
4.2.67 Cooling-fan speed drop signal (WAF) (C021 to C026, b092 to d022)·························4 - 67
4.2.68 Starting contact signal (FR) (C021 to C026)································································4 - 67
4.2.69 Heat sink overheat warning signal (OHF) (C021 to C026, C064) ·······························4 - 67
4.2.70 Low-current indication (LOC) signal (C021 to C026, C038, C039) ·····························4 - 68
4.2.71 Inverter ready signal (IRDY) (C021 to C026) ······························································4 - 68
4.2.72 Forward rotation signal (FWR) (C021 to C026)···························································4 - 68
4.2.73 Reverse rotation signal (RVR) (C021 to C026) ···························································4 - 69