Chapter 4 Explanation of Functions
4 - 75
4.2.83 Initialization setting
Function code
b084: Initialization mode (parameters
or trip history)
b085: Country code for initialization
Related code
The initialization function allows you to initialize the adjusted settings on
the inverter to restore the factory settings. You can also clear the trip
history data alone.
The settings of initialization are described below.
The settings of "P100" to "P131", running-time data, and power-on time data cannot be cleared.
Item Data Description
00 Clearing on the trip history data
01
Initializing only the settings
The factory settings are restored.
Initialization mode
(parameters or trip
history)
b084
02
Clearing the trip history data and initializing the
settings
00 Defaults intended for Japan
01 Defaults intended for Europe
Country code for
initialization
b085
02 Defaults intended for the U.S.A.
(Initializing procedure)
Adjust the above settings as required, and then perform the following procedure:
RUN
STOP/
RESET
RUN
STOP/
RESET
RUN
STOP/
RESET
FUNC STR FUNC STR FUNC STR
Note 2: The initialization operation does not initialize the settings of easy sequence user parameters
(P100 to P131).
1) Holding down the FUNC and [2]
(down) keys, press and hold down
the STOP/RESET key.
- After the monitor starts blinking,
release only the STOP/RESET
key. (The display on the monitor
changes to that shown in the
middle figure above.
- Release the FUNC and [2]
(down) keys.
2) Initialization is in progress.
- The above figure shows the
monitor display (indicating that the
initialization is in progress)
intended for Japan. Those
intended for other regions and trip
history clearance are shown
below.
3) When the initialization is
completed, the monitor displays
code "d001".
Confirm that the settings have
been initialized.
Initialization-in-progress
display intended for Europe
Initialization-in-progress display for
trip history clearance
In the far-left digit, the lighting
segments move round for
Initialization-in-progress
display intended for the U.S.A.
Note 1: The initialization operation does not initialize the analog input settings (C081, C082, C083, C121,
C122, and C123) and thermistor coefficient setting (C085).