Hitachi SJ700-2 Power Supply User Manual


 
Chapter 4 Explanation of Functions
4 - 142
(6) List of registers
The "R/W" column of the list indicates whether the coils and registers are read-only or readable and
writable.
"R" indicates a read-only coil or register. "R/W" indicates a readable and writable coil or register.
(i) List of coils
Coil No. Item R/W Setting
0000h (Reserved) -
0001h Operation command R/W 1: Run, 0: Stop (valid when A002 = 03)
0002h Rotation direction command R/W 1: Reverse rotation, 0: Forward rotation (valid when A002 = 03)
0003h External trip (EXT) R/W 1: Trip
0004h Trip reset (RS) R/W 1: Reset
0005h (Reserved) -
0006h (Reserved) -
0007h Intelligent input terminal [1] R/W 1: ON, 0: OFF (*1)
0008h Intelligent input terminal [2] R/W 1: ON, 0: OFF (*1)
0009h Intelligent input terminal [3] R/W 1: ON, 0: OFF (*1)
000Ah Intelligent input terminal [4] R/W 1: ON, 0: OFF (*1)
000Bh Intelligent input terminal [5] R/W 1: ON, 0: OFF (*1)
000Ch Intelligent input terminal [6] R/W 1: ON, 0: OFF (*1)
000Dh Intelligent input terminal [7] R/W 1: ON, 0: OFF (*1)
000E Intelligent input terminal [8] R/W 1: ON, 0: OFF (*1)
000Fh Operation status R 1: Run, 0: Stop (interlocked to "d003")
0010h Rotation direction R 1: Reverse rotation, 0: Forward rotation (interlocked to "d003")
0011h Inverter ready R 1: Ready, 0: Not ready
0012h Unused R
0013h RUN (running) R 1: Tripping, 0: Normal
0014h FA1 (constant-speed reached) R 1: ON, 0: OFF
0015h FA2 (set frequency overreached) R 1: ON, 0: OFF
0016h OL (overload notice advance signal (1)) R 1: ON, 0: OFF
0017h OD (output deviation for PID control) R 1: ON, 0: OFF
0018h AL (alarm signal) R 1: ON, 0: OFF
0019h FA3 (set frequency reached) R 1: ON, 0: OFF
001Ah OTQ (over-torque) R 1: ON, 0: OFF
001Bh IP (instantaneous power failure) R 1: ON, 0: OFF
001Ch UV (undervoltage) R 1: ON, 0: OFF
001Dh TRQ (torque limited) R 1: ON, 0: OFF
001Eh RNT (operation time over) R 1: ON, 0: OFF
001Fh ONT (plug-in time over) R 1: ON, 0: OFF
0020h THM (thermal alarm signal) R 1: ON, 0: OFF
0021h (Reserved) -
0022h (Reserved) -
0023h (Reserved) -
0024h (Reserved) -
0025h (Reserved) -
0026h BRK (brake release) R 1: ON, 0: OFF
0027h BER (brake error) R 1: ON, 0: OFF
0028h ZS (0 Hz detection signal) R 1: ON, 0: OFF
0029h DSE (speed deviation maximum) R 1: ON, 0: OFF
002Ah POK (positioning completed) R 1: ON, 0: OFF
002Bh FA4 (set frequency overreached 2) R 1: ON, 0: OFF
002Ch FA5 (set frequency reached 2) R 1: ON, 0: OFF
002Dh
OL2 (overload notice advance signal
(2))
R 1: ON, 0: OFF
002Eh Odc: Analog O disconnection detection -
002Fh
OIDc: Analog OI disconnection
detection
-
0030h
O2Dc: Analog O2 disconnection
detection
-
0031h (Reserved) -
0032h FBV (PID feedback comparison) R 1: ON, 0: OFF
0033h
NDc (communication train
disconnection)
R 1: ON, 0: OFF
0034h LOG1 (logical operation result 1) R 1: ON, 0: OFF