Setting of slide switch SW1 setting and function selection for intelligent input terminals [1] and [3]
Intelligent input terminal [1] Intelligent input terminal [3]
Setting of slide switch
SW1
Terminal [1] function [C001]
a/b (NO/NC) selection
[C011] (*1)
Terminal [3] function [C003]
a/b (NO/NC) selection
[C013] (*1) (*2)
Selectable arbitrarily (*4) Selectable arbitrarily (*4) Selectable arbitrarily (*4) Selectable arbitrarily (*4) SW1 is OFF.
Emergency stop
disabled
(factory setting)
Factory
setting
18 (RS)
Factory
setting
00 (NO)
Factory
setting
06 (JG)
Factory
setting
00 (NO)
Automatic assignment of functions to intelligent input terminals [1] and [3] and the terminal to which function "18 (RS)" has
been assigned (*3)
SW1 is ON.
Emergency stop
enabled (*5)
Fixed function
(cannot be
changed)
18 (RS)
Fixed function
(cannot be
changed)
00 (NO)
Fixed function
(cannot be
changed)
64 (EMR)
Fixed function
(cannot be
changed)
01 (NC)
Selectable arbitrarily (*4) Selectable arbitrarily (*4) Selectable arbitrarily (*4) Selectable arbitrarily (*4)
SW1 is ON (after
setting to OFF once).
Emergency stop
disabled (*3) (*5)
Setting made
when SW1 is
set ON
retained
18 (RS)
Setting made
when SW1 is
set ON
retained
00 (NO)
Released
from
emergency
stop function
no
(No function
assigned)
Setting made
when SW1 is
set ON
retained
01 (NC)
*1 When function "18 (RS)" is assigned to the input terminal, "a/b (NO/NC)" selection is always "00 (NO)".
*2 When terminal setting "C003" is "64 (EMR)", terminal setting "C013" is always "01 (NC)".
*3 If function "18 (RS)" has been assigned to an intelligent input terminal other than intelligent input terminals [1] and [3] before slide
switch SW1 is set to ON, the input terminal setting for said terminal is automatically changed to "no (no function assigned)" when
slide switch SW1 is set to ON to prevent any duplication of terminal functions. Even if slide switch SW1 is subsequently returned
to OFF, the original function setting for said terminal will not be restored. If necessary, the original function will have to be
re-assigned to said terminal.
Example: If slide switch SW1 is set to ON when function "18 (RS)" has been assigned to input terminal 2 (by terminal setting
"C002"), terminal setting "C002" is changed to "no (no function assigned)," and function "18 (RS)" is assigned to input terminal 1
(by terminal setting "C001").
Even if slide switch SW1 is subsequently returned to OFF, terminal [2] function "C002" and terminal [1] function "C001" will
remain as "no (no function assigned)" and "18 (RS)," respectively.
*4 Function "64 (EMR)" cannot be assigned to input terminal 3 by an operation from the digital operator. The function is
automatically assigned to the terminal when slide switch SW1 is set to ON.
*5 After slide switch SW1 has been set to ON once, function assignments to intelligent input terminals [1] and [3] are not returned to
their original assignments. If necessary, re-assign original functions to the intelligent input terminals.
ON
Slide switch SW1
OFF ON
Slide lever (factory setting: OFF)
Note: If the data of an optional operator (SRW or SRW-EX) is copied:
If operator data is copied to your SJ700 series inverter whose slide switch SW1 is ON from another SJ700 series inverter
whose slide switch SW1 is OFF or an SJ300 series inverter, the digital operator on your SJ700 series inverter may display
[R-ERROR COPY ROM] for a moment. This event may occur because the data on intelligent input terminals [1] and [3]
cannot be copied since, on your inverter, exclusive functions have already been assigned to intelligent input terminals [1] and
[3] due to the slide switch SW1 setting to ON. Note that other data is copied. If this event occurs, check the settings on both
copy-source and copy-destination inverters.
(Remark) To reflect the copied data, power off and on again after copy completed.
2 - 10