IBM RELEASE 7.3 Computer Drive User Manual


 
5.1.1.2.1. AML PVR Information Window
Field Descriptions
Server Name. The descriptive name of the PVR.
Total Cartridges. The number of cartridges currently being managed by the PVR.
Cartridge Capacity. The total number of cartridge slots in the library dedicated to this HPSS PVR.
This may or may not be the total cartridge capacity of the library; a site might use part of the library for
some other HPSS PVR or for some non-HPSS application. The PVR uses the Cartridge Capacity field
and the Cartridge Alarm Threshold field to determine when to send an alarm that the total cartridge
threshold has been exceeded.
Cartridge Alarm Threshold. The percentage of the Cartridge Capacity at which the PVR will send an
alarm.
Same Job on Controller, Other Job on Controller, & Distance To Drive. These values are used by the
PVR when selecting a drive for a tape mount operation. The three values are essentially weights that are
used to compute an overall score for each possible drive. After the score has been calculated, the drive
with the lowest score is selected for the mount. If two or more drives tie for the lowest score, one drive is
selected at random. The score is calculated as follows:
Score =
Weight 1 * Cartridges from this job mounted on this drive’s controller +
Weight 2 * Cartridges from other jobs mounted on this drive’s controller +
Weight 3 * Units of distance from the cartridge to the drive
This method has the effect of distributing a striped tape mount across as many controllers as possible for
the best performance. It also will try to pick controllers that are currently driving a minimum number of
tapes. So, in an environment with many tape drives per controller, the above algorithm will minimize the
load on any one controller.
The Distance To Drive helps minimize mount times by mounting the tape in a physically close drive. All
other things being equal, the tape will be mounted in the closest drive. However, if the closest drive is
attached to a heavily used controller, then a more distant drive will be selected.
Retry Mount Time Limit. The default value for this field is -1. When the default value (-1) is used, if an
error is encountered during a PVR mount operation, the mount will pend and be retried every 5 minutes.
Setting a value in this field will change the mount behavior to periodically retry the mount until the
specified time limit is exceeded. Once exceeded, an error is generated and the mount request is canceled.
If the mount request would have resulted in a write operation, the error returned will cause the Core
Server to set the VV Condition of the associated tape volume to DOWN. Once in DOWN state, the
volume will no longer be available for read or write operations. For further information about the Core
Server VV Condition, see Section 4.5.4.2: Core Server Tape Volume Information Window on page 271.
Drive Error Limit. This field is used in conjunction with the PVR Server Retry Mount Time Limit. If
HPSS Management Guide November 2009
Release 7.3 (Revision 1.0) 138