CHAPTER 18
Power and Electrical Safety Information
General Electrical Safety Guidelines and Warnings for EX Series Switches on page 141
Prevention of Electrostatic Discharge Damage on EX Series Switches on page 142
AC Power Electrical Safety Guidelines for EX Series Switches on page 144
AC Power Disconnection Warning for EX Series Switches on page 145
TN Power Warningfor EX Series Switches on page 146
In Case of Electrical Accident: Action to Take on an EX Series Switch on page 147
General Electrical Safety Guidelines and Warnings for EX Series Switches
This topic applies to hardware devices in the EX Series product family, which includes
switches and the XRE200 External Routing Engine.
WARNING: Certain ports on the device are designed for use as intrabuilding
(within-the-building) interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE,Issue4)andrequireisolationfromtheexposedoutsideplant
(OSP) cabling. To comply with NEBS requirements and protectagainst
lightningsurgesandcommercialpower disturbances, theintrabuildingports
must not be metallically connected to interfaces that connect to the OSP or
its wiring. The intrabuilding ports on the device are suitable for connection
to intrabuilding or unexposed wiring or cabling only.The addition of primary
protectors is not sufficient protection forconnecting these interfaces
metallically to OSP wiring.
CAUTION: Before removing or installing components of a device, attach an
ESD strap to an ESD point and place the other end of the strap around your
bare wrist. Failure to use an ESD strap could result in damage to the switch.
Install the device in compliance with the following local, national, and international
electrical codes:
141Copyright©2010,Juniper Networks,Inc.