Minolta Scanner Mode Scanner User Manual


 
13
Specifying Management Settings
13-54 Scanner Mode
13.13.9Specifying Settings Concerning the Timeout for a DNS
Inquiry (Mode 367)
You can specify the time until a connection with the DNS server times out.
Setting during production
Specifying the setting
During the production of this unit, the settings in the shaded cells were
selected. The numbers on the right side are page number with
descriptions for the corresponding function.
Bit 76543210
Setting 00100000(HEX:20)
Bit Function Setting Description
Page
referen
ce
7, 6, 5,
4, 3
Time until a connection
with the DNS server times
out
00001 30 seconds p. 3-3
00010 40 seconds
00011 80 seconds
00100 160 seconds
00101 320 seconds
00110 640 seconds
Others *Do not specify any
settings other than those
mentioned above.
2, 1, 0 -
000 *Do not change these bits. -