Paradyne CPX-1000 Network Card User Manual


 
February 2003 D-3
1000-A2-GN22-00 D. Specifications
Table D–2. CPX-1000 Environmental Specifications
Parameter Specification Reference
Operating temperature 5 C to 40 C (40 F to 104 F) GR-63-CORE, R4-6, R4-7
Operating humidity 5% to 85% RH, non-condensing GR-63-CORE, R4-6, R4-7
Storage and transit temperature –40
C to +70 C (–40 F to 158 F) GR-63-CORE, R4-3, R4-4
Storage and transit humidity 95% RH at 40
C (104 F) GR-63-CORE, R4-5
Altitude
without temperature derating
60m to 1800m above sea level
200 ft to 5905 ft)
GR-63-CORE, R4-8
with temperature derating 1800 to 4000m above sea level
(5095 ft to 13,123 ft)
GR-63-CORE, R4-9, O4-
10
Airborne contaminant 25 ppi pore size, 63% dust
arrest. UL-900 Class V-2, UL 94
H-1 flammability rated
GR-63-CORE, 4.5, R4-59,
O4-60
Table D–3. CPX-1000 Electrical Specifications
Parameter Specification Reference/Comment
Electrical safety criteria GR-1089-CORE,
Section 7.0
Bonding and grounding Common, integrated ground plane,
multi-point ground
GR-1089-CORE,
Section 9.0
Input voltage range –40 VDC to –72 VDC A and B input
Corrosion GR-1089-CORE,
Section 8.0