13.6.1 Supported MIBs
The WR3000 Wireless Router supports MIB II that is defi ned in RFC-1213 and RFC-1215.
The focus of the MIBs is to let administrators collect statistical data and monitor status and
performance.
13.6.2 SNMP Traps
The WR3000 Wireless Router will send traps to the SNMP manager when any one of the
following events occurs:
SNMP Traps
TRAP*
TRAP*
TRAP NAME
DESCRIPTION
DESCRIPTION
1
coldStart
coldStart
(defi ned in RFC-1215)
(defi ned in RFC-1215)
A trap is sent after booting (power on).
A trap is sent after booting (power on).
2
warmStart
warmStart
(defi ned in RFC-1215)
(defi ned in RFC-1215)
A trap is sent after booting (software reboot).
A trap is sent after booting (software reboot).
3
NnkUp
(defi ned in RFC-1215)
(defi ned in RFC-1215)
A trap is sent when the port is up.
4
authenticationFailure
(defi ned in
(defi ned in
RFC-1215)
A trap is sent to the manager when receiving any
SNMP get or set requirements with wrong community
(password).
6
NnkDown
(defi ned in RFC-1215)
(defi ned in RFC-1215)
A trap is sent when the port is down.
The following table maps the physical port and encapsulation to the interface type.
Ports and Interface Types
PHYSICAL PORT/ENCAP
PHYSICAL PORT/ENCAP
INTERFACE TYPE
INTERFACE TYPE
LAN port(s)
LAN port(s)
enetO
enetO
Wireless port
eneti
PPPoE encap
PPPoE encap
pppoe
pppoe
1483 encap
mpoa
Ethernet encap
enet-encap
PPPoA
PPP