Pelco Manual C1515M-A (11/01) 35
GENEX MULTIPLEXER
Access the Camera programming screen and specify MUX control for all cameras
connected to the CM6800 through the Genex Multiplexer.
Access the CM6800 Camera programming screen to configure the following camera control
options for each camera connected to the CM6800 through the Genex Multiplexer:
CONTROL: MUX
PORT ADDRESS: assign the appropriate address. The port address must match
the “Unit ID” assigned through the Genex programming screens.
You must also configure the Genex Multiplexer. Refer to the MX4000 Genex Series
Simplex and Duplex Multiplexers Installation/Operation Manual (C1920M-B) for instructions
on accessing the Advanced System Setup programming screen. Select the following
options:
SPOT MONITOR DISPLAY: TRACK MAIN
UNIT ID (must match the port address assigned through the CM6800)
COMM. TYPE: SLAVE (each multiplexer connected to the CM6800 must be in
slave mode)
MONITOR COLOR ADJUSTMENT:
Once you have connected all devices and powered the system, use the CM6800 color bars
as a reference tool for adjusting the color on each monitor.
1. Enter 9999.
2. Press the CAM key. Broadcast quality color bars appear on the monitor.
3. Adjust color on each monitor as necessary until the color bars match the following
color order on the monitor (for black and white monitors you can use the color bars to
adjust brightness):
00630
Figure 27. CM6800 Color Bars
PROGRAM PRESETS
Program presets as necessary for your system. Refer to the appropriate keyboard manual
for instructions.
ADDITIONAL PROGRAMMING
Refer to the
Programming
section for complete instructions on programming the CM6800.
System
Start-Up