Pelco c1515m-a Switch User Manual


 
76 Pelco Manual C1515M-A (11/01)
Desired Action
Auxiliary on
Auxiliary off
Camera auxiliary on
Camera auxiliary off
Start macro
Stop macro
Acknowledge alarm
Arm internal alarm
Arm external alarm
Arm video loss alarm
Disarm internal alarm
Disarm external alarm
Disarm video loss alarm
Send camera title
Version
Set date and time
Command
[1-128]xa
[1-128]~xa
[1-8]Aa
[1-8]Ba
[1-32]Sa
[1-32]Ha
[1-9999]Ia
[1-8]Ji
[1-128]Je
[1-48]Jv
[1-8]~Ji
[1-128]~Je
[1-48]~Jv
[1-48]Ya[string]!a
va
ZaMM/DD/YY/HH:
MM:Ssa
Result
Auxiliaries are relay outputs that can be controlled through the protocol 1-3
operate the AUX 1-2 and F3 auxiliaries on the rear panel of the CM6800
(and the first three auxiliaries on an external REL2064). 4-128 operate the
external auxiliaries on up to two REL2064 Relay Interface Units.
Operates auxiliaries at the camera (receiver).
Starts the selected macro.
Stops the selected macro.
Acknowledges an existing alarm.
These commands arm and disarm system alarms.
Sends a camera title to the matrix switching system. You can only send
one camera title at a time.
Valid characters in the string are A-Z, a-z, space, and 0-9 in ASCII
representation. Strings are limited to 20 characters.
Returns the version number of the device.
Sets the date and time. Since the date and time string could be
confused with other commands, the command Za comes first. This puts
the receiving device into a mode that can accept the specialized string.
NOTE: All transmitted characters must be ASCII.
Table J. ASCII Commands (Continued)
Appendix