Pelco c1515m-a Switch User Manual


 
Pelco Manual C1515M-A (11/01) 43
BLOCK BUILD
Alarmed cameras are displayed across a block of alarm monitors in a sequential order. All
steps programmed for the alarm contact appear on the designated monitor.
Example: Eight alarms set to display on monitors 02-07 will appear in the following order:
1st Display Next Display Acknowledging Next Display
Monitor Cycle Cycle Alarms 1 & 2 Cycle
02 B 1st alarm 1st and 7th Acknowledge 7th alarm
alarms cycle 1st alarm
03 B 2nd alarm 2nd and 8th Acknowledge 8th alarm
alarms cycle 2nd alarm
04 B 3rd alarm 3rd alarm 3rd alarm 3rd alarm
05 B 4th alarm 4th alarm 4th alarm 4th alarm
06 B 5th alarm 5th alarm 5th alarm 5th alarm
07 B 6th alarm 6th alarm 6th alarm 6th alarm
New alarms display on the lowest monitor number with the fewest alarms cycling.
CHRONOLOGICAL PAIR: D AND Q
The oldest alarm of a specific group is displayed on one designated monitor, while all other
alarms in the group are sequenced on the second designated monitor. All steps pro-
grammed for the alarm contact appear on the designated monitor.
Example: Four alarms set to display on monitors 04 and 05 will appear in the following order:
Monitor 1 Alarm 2 Alarms 3 Alarms 4 Alarms
04 D 1st alarm 1st alarm 1st alarm 1st alarm
05 Q 2nd alarm 2nd and 3rd 2nd, 3rd, and 4th
alarms cycle alarms cycle
You must acknowledge alarms in a chronological pair from the display monitor (D). Then
the next oldest alarm moves to the display monitor and the remaining alarms continue to
cycle through the queue monitor (Q). This format requires you to acknowledge each alarm
in the order in which they occur.
Acknowledging alarms in this example:
Monitor 1st Cycle Next Cycle Next Cycle Next Cycle
04 D Acknowledge Acknowledge Acknowledge Acknowledge
1st alarm 2nd alarm 3rd alarm 4th alarm
05 Q 2nd, 3rd, and 4th 3rd and 4th 4th alarm
alarms cycle alarms cycle
ALARM MONITOR GROUP SETUP
MON A B C D E F G H
01 ————
02 B ————
03 B ————
04 B ————
05 B ————
06 B ————
07 B ————
08 ————
HELP
00638
ALARM MONITOR GROUP SETUP
MON A B C D E F G H
01 ————
02 ————
03 ————
04 D ————
05 Q ————
06 ————
07 ————
08 ————
HELP
00640
Alarm
Programming