TIME OUT: Enter the amount of time (0-99 seconds) alarm remains active after the
contact has cleared (AUTO alarms only).
TYPE: Select the alarm input type (Internal Alarms only).
OPTIONS:
N.O. = normally open
N.C. = normally closed
PRIORITY: Select the priority level of the alarm; a priority alarm appears on
system monitors before a non-priority alarm.
OPTIONS:
0 = non-priority
1 = priority
STP: Each alarm contact can include up to eight steps to be activated as a
result of this alarm. For each step select entries in the following fields as
necessary.
CAM: Enter the logical number of the camera to be
displayed; must be a valid logical number (0001-9998).
DWL: Enter the amount of time the camera view is
displayed in an alarm sequence (0-99 seconds); to
enable the alarm contact you must set at least one
camera with a dwell time greater than 0.
CMD and ##: Select a camera operation; if you select a pattern or
a preset, enter a valid pattern or preset number.
OPTIONS:
PRES = preset
PATT = pattern
RSCN = random scan
FSCN = frame scan
SSCN = stop scan
AUX and ##: Select an auxiliary to be activated.
Global = internal and external auxiliaries.
OPTIONS:
GON = turn global auxiliary on (1-128)
GOFF = turn global auxiliary off (1-128)
CON = turn camera auxiliary on (1-8)
COFF = turn camera auxiliary off (1-8)
GROUP ENABLE: Assign the alarm contact to one or more alarm groups (A through H).
OPTIONS:
Y = include in group
N = do not include in group
NOTE:
The auxiliaries on
the rear panel of the
CM6800 are activated by
global auxiliary numbers 1,
2, and 3
Alarm
Programming