Pelco c1515m-a Switch User Manual


 
60 Pelco Manual C1515M-A (11/01)
PRIORITY CONTROL
The CM6800 provides eight levels of priority control. Each level defines the ability of a
keyboard to control a pan/tilt/zoom (camera positioning system) and to access program-
ming screens.
Priority level applies system wide; a keyboard assigned priority level 2 on COM port 8 has a
higher priority than a keyboard assigned priority level 4 on COM port 5. A higher level
keyboard takes precedence over a lower level keyboard when the keyboards are issuing
control commands.
NOTE:
You can connect
only one ASCII keyboard/de-
vice per port on the CM6800
(COM port 1, 2, 4, 7, or 8).
For ASCII keyboards priority
control is based on the entry
for keyboard 1.
Figure 48. Access the Priority Screen
PORT: Select the COM port number for which you are programming priority
control.
PRIORITY: For each keyboard connected to the specified port, assign a priority level
(01-08).
OPTIONS:
Level 1 = highest priority
Level 8 = lowest priority
Levels 1 - 4 have the ability to access programming screens. Levels
5-8 cannot access programming screens. The lowest level or
keyboards located at the same level will access devices on first-come,
first-served basis.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
1 CAMERA
2 LOGICAL CAMERA
3 MONITOR
4 ACCESS
5 TIME & DATE
6 PORT
7 PRIORITY
8 SEQUENCE
9 MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00654
KEYBOARD PRIORITY MENU
PORT 05
KBD PRIORITY
101
202
308
408
508
608
708
808
RETURN
00658
Priority
Programming