50 Pelco Manual C1515M-A (11/01)
CAMERA
Use the Camera screen to configure settings for each camera connected to the CM6800.
Figure 38. Access the Camera Screen
CAMERA: Select the logical number of the camera (video input) to be defined
(0001-9998).
NOTE:
To select logical numbers other than the default numbers
(001 to 0048) you must first program the logical numbering in the Logical
Camera screen. Refer to
Logical Camera Numbers
in this section.
VERTICAL DRIVE: Enable Vertical Drive (ON) to synchronize Pelco cameras that have the
ability to accept a synchronization pulse via the coax cable.
CONTROL: Select the receiver control type for the device connected to this input;
that is, the type of receiver communication you will use to control a
camera’s pan and tilt and lens (if applicable).
OPTIONS:
EXT COAX: Coaxitron extended mode (32-bit)
STD COAX: Coaxitron standard mode (15-bit)
MUX: Genex multiplexer
PTZ-A: RS-422 Control Port A
PTZ-B: RS-422 Control Port B
NOTE:
If you select PTZ-A or PTZ-B you must also specify the port
address (in the following field) and program Serial Port 9 or 10 (refer to
Ports
in this section).
PORT ADDRESS: Required only for Genex multiplexer or RS-422 control.
Genex multiplexer: Select the address of the multiplexer (01-32); this
address must match the unit ID specified through multiplexer program-
ming. Refer to the MX4000 Genex Series Simplex and Duplex
Multiplexers Installation/Operation Manual.
RS-422 cameras connected through PTZ-A or PTZ-B: Select the
camera/device address for RS-422 control (01-32). The port address
must match the address setting configured through the camera/
receiver DIP switch settings.
CAMERA TITLE: The camera title (up to 20 alphanumeric characters) appears on the
monitor during real-time camera display (refer to
Monitor Display
in this
section). Use F1 and F2 to scroll through the characters; once you
reach the desired character for a position, navigate to the next position.
The default characters are 26 upper case letters and the numbers 0-9.
You can add special characters, such as letters with accent marks
used in other languages, through the CM6800-MGR (refer to the
CM6800-MGR Quick Start Guide).
PELCO SWITCHER
MODEL CM6800
MAIN MENU
1 CAMERA
2 LOGICAL CAMERA
3 MONITOR
4 ACCESS
5 TIME & DATE
6 PORT
7 PRIORITY
8 SEQUENCE
9 MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00654
CAMERA 0001
VERTICAL DRIVE: OFF
CONTROL: EXT COAX
PORT ADDRESS: 01
CAMERA TITLE:
CAM 1
RETURN
00646
NOTE:
The following Pelco
cameras are compatible
with the vertical drive option:
CC3500H-2
CC3500S-2
CC3600H-2
CC3551H-2
MC3600H-2
MC3651H-2
MC3500S-2
Camera
Programming