Pelco c1515m-a Switch User Manual


 
Pelco Manual C1515M-A (11/01) 57
TEST POSITIONING MENU
PRESS PGM EXIT
- - -- - -
00633
MON/ALM NUMBER: Enable (ON) or disable (OFF) on-screen display of the monitor/
alarm number. During normal operation, the monitor number
appears in this field. The monitor number is a fixed number,
representing an actual BNC output on the rear panel of the CM6800.
When an alarm is active, the alarm number appears in this field. The
alarm number represents an alarm contact – the physical alarm
input number of an internal alarm contact, or the address of an
external alarm contact as configured on the Alarm Interface Unit.
MON/ALM STATUS: Enable (ON) or disable (OFF) on-screen display of the monitor or
alarm status.
MONITOR STATUS DISPLAY VALUES:
Blank = normal status
H = hold
S = sequence
NOTE:
If an operator presses the HOLD key while an alarm
appears on the monitor, the H does not appear. The alarm icon and
alarm status value blink to indicate the HOLD status.
ALM STATUS DISPLAY VALUES:
I = internal alarm
E = external alarm
V = video loss alarm
TIME: Enable (ON) or disable (OFF) on-screen display of the time as
programmed in the system.
DATE: Enable (ON) or disable (OFF) on-screen display of the date as
programmed in the system.
BRIGHTNESS: Select the brightness level of the on-screen display (1-8; 8 = white
characters, 1 = black characters; 2-7 = shades of gray).
If you select CURRENT in the MONITOR field, you can see the
brightness level change as you scroll through the options.
If you select ALL in the MONITOR field, the changes do not take
effect until you apply changes in the SET ALL field.
POSITION DISPLAY: Navigate left or right to select the Test Positioning Menu.
The real-time camera display appears with Test Positioning Menu
text superimposed on the screen. Use the position keys or joystick
to move the text to the desired position on the screen. The text
moves one line or character position at a time.
Press the PGM key to exit the test positioning menu.
SET ALL: To apply monitor display changes to all system monitors (if you
selected ALL in the MONITOR field) you must navigate left or right in
the SET ALL field; otherwise monitor display settings are not
changed.
If you selected CURRENT in the MONITOR field, navigating left or
right in the SET ALL field has no effect.
00620
00620
0001 E CAM 1
0001 V 01-JAN-01 01:01:01
V
00634
00620
Monitor
Programming