Pitney Bowes DM800 Postal Equipment User Manual


 
SV61162 Rev. C 5-31
DM800™ Series Digital Mailing System Operating Guide
15
Setting Up
the Optional
Smart Class™
Feature
Using Smart Class™ you can process up to 4 different postal classes with-
in the same mail run without having to pre-weigh or sort the mail by class
before the run.
Smart Class™ is an exclusive Pitney Bowes capability that enables you to
process mail at the lowest available postal rate in a single step, eliminating
costly time that operators spend to pre-weigh or sort the mail by class be-
fore the run, or without interrupting the mail system during the mail run.
Setting up Smart Class™
The following example shows how to set 3 different weight breaks. The
weight breaks will use the following three classes.
For weight break: Use Class:
0.0 oz to 3.0 oz 1st Class Automation Letter 5 Digit
3.0 oz to 13.0 oz 1st Class Non-Automation Presort
13.o oz to 1.0 lb Priority
1. Press the
Menu key.
2. Select
Set Up, then press the down arrow and select Scales/Rates.
3. Press the down arrow (depending on your system you may have to
press it twice) and select Smart Classes.
4. Select
Create.
5. Select the appropriate Carrier, in this example,
USPS Domestic.
a. You are prompted to enter the maximum weight for this weight
break:
Enter the max weight for this
weight break
0 lb 0.0 oz to __lb __oz
b. To set the first weight break, use the numeric keys and enter 0 for
lb. Press the Enter key.
Enter 3 for oz and press the
Enter key.
c. Select the appropriate class, in this example, 1st Class Au
to.
d. Select the appropriate subclass. In this example, select Letter,
then select 5-Digit.
Press
Enter.