Q-Logic 59048-02 A Switch User Manual


 
A – Command Line Interface
Set Config Command
59048-02 A A-37
Q
zoning
Initiates an editing session in which to change switch zoning attributes. The
system displays each parameter one line at a time and prompts you for a value.
For each parameter, enter a new value or press the Enter key to accept the
current value shown in brackets.
Rising Trigger The event count above which a rising threshold
alarm is logged. The switch will not generate
another rising threshold alarm for that event until
the count descends below the falling threshold
and again exceeds the rising threshold.
Falling Trigger The event count below which a falling threshold
alarm is logged. The switch will not generate
another falling threshold alarm for that event until
the count exceeds the rising threshold and
descends again below the falling threshold.
Sample Window The period of time in seconds in which to count
events.
Table A-12. Set Config Zoning Parameters
Parameter Description
FC-SW-2 AutoSave Available only when the FC-SW-2
Compliant parameter is True, this
parameter enables (True) or disables
(False) the saving of changes to active
zone set in the switch’s permanent
memory. Refer to ”FC-SW-2 Compliant” on
page A-36. The default is True.
Default Enables (All) or disables (None)
communication among the switch’s ports/
devices and the fabric in the absence of an
active zone set. The default is All.
Table A-11. Set Config Threshold Parameters (Continued)
Parameter Description