A – Command Line Interface
Test Command
59048-02 A A-75
Q
Test Command
Tests I/O blades and ports using internal (SerDes level), external (SFP), and
online loopback tests. Internal and external tests require that the port be placed in
diagnostic mode. Refer to the ”Set Command” on page A-30 for information about
changing the I/O blade or port administrative state. While the test is running, the
remaining ports on the switch remain fully operational.
Authority Admin
Syntax test
blade [slot_number]
port [port_number] [test_type]
cancel
status
Keywords blade [slot_number]
Tests the ASIC registers and performs an internal SerDes test on all ports on the I/
O blade that occupies the slot given by [slot_number]. I/O blade slot numbers are
1–4 and 6–9. The I/O blade must be in diagnostics mode to perform this test.
port [port_number] [test_type]
Tests the port given by [port_number] using the test given by [test_type]. If you
omit [test_type], Internal is used. [test_type] can have the following values:
internal
Tests the SerDes. This is the default. The port must be in diagnostics mode
to perform this test.
external
Tests both the SerDes and SFP. The port must be in diagnostics mode to
perform this test, and a loopback plug must be installed in the SFP.
online
Tests one online port.
cancel
Cancels the online test in progress.
status
Displays the status of a test in progress, or if there is no test in progress, the
status of the test that was executed last.
Examples To run an internal (SerDes) or external (SFP) port test, do the following:
1. To start an admin session, enter the following command and press the Enter
key.
admin start
2. Place the port in Diagnostics mode, enter the following command (x = port
number) and press the Enter key.
set port x state diagnostics