SANRAD I3.1.1205 Switch User Manual


 
Chapter 11: Command Line Interface 11-29
subdisk alias
This command allows you to view all subdisk aliases in full. The command
subdisk show has a ten-character display limit so subdisk aliases may be
ambiguous in the subdisk show table.
subdisk alias
Table 11-20: Subdisk Aliases
Disk Length Alias
Disk3 1024 split1disk3
Disk7 1024 split1disk7
Disk7 1024 split2mirror
subdisk set
This command renames a subdisk and allows you to edit the subdisk
information.
subdisk set
SWITCH PARAMETER DEFINITION STATUS EXAMPLE
-sd
SUBDISK ALIAS ALIAS OF SUBDISK
TO RENAME
MANDATORY
sub1
-na
NEW SUBDISK ALIAS NEW ALIAS OF
SUBDISK
MANDATORY IF
CHANGING THE
ALIAS
mir1
-info
INFORMATION INFORMATION ON
SUBDISK FOR LOCAL
ADMINISTRATION
ONLY
MANDATORY IF
CHANGING
subdisk remove
This command removes a specified subdisk.
subdisk remove
SWITCH PARAMETER DEFINITION STATUS EXAMPLE
-sd
SUBDISK ALIAS ALIAS OF SUBDISK
TO DELETE
MANDATORY
sub1