SANRAD I3.1.1205 Switch User Manual


 
A-6 SANRAD V-Switch User Manual
STEP 8. CHECK STORAGE DEVICES
Use the CLI command storage show to list the system-registered
storage devices. This ensures that all disks were registered during the disk
auto-discovery scan. This also lists the default disk aliases needed for
creating your simple volumes.
storage show
Table A-3: Storage Devices
Alias Entity Name LUN Oper. Status Type
Stor_1 500507606058c90 0 Enabled disk
Stor_2 2000002037f88fb8 0 Enabled disk
Stor_3 2000002037c32b1f 0 Enabled disk
Stor_4 2000002037c32450 0 Enabled disk
STEP 9. C
REATE SIMPLE VOLUMES
Use the CLI command volume create simple to create four simple
virtual volumes – one from each physical disk.
volume create simple –vol Simple1 –d Stor_1
volume create simple –vol Simple2 –d Stor_2
volume create simple –vol Simple3 –d Stor_3
volume create simple –vol Simple4 –d Stor_4
STEP 10. C
REATE MIRRORED VOLUMES (RAID 1)
Use the CLI command volume create mirror to create a mirrored
volume, Mirror1, from simple volumes Simple1 and Simple2.
volume create mirror –vol Mirror1 –nbc 2 –ch
Simple1 –ch Simple2
Use the CLI command volume create mirror to create a mirrored
volume, Mirror2, from simple volumes Simple3 and Simple4.
volume create mirror –vol Mirror2 –nbc 2 –ch
Simple3 –ch Simple4