SANRAD I3.1.1205 Switch User Manual


 
12-2 SANRAD V-Switch CLI User Manual
Health Monitoring
You can monitor the health of the V-Switch hardware for fan malfunctions that
could lead to overheating as well as power supply malfunctions both of which
can nullify high availability and lead to V-Switch failover.
system hardware show
This command shows all hardware interface connection statistics.
system hardware show
Table 12-1: System Hardware
Max No. of Power Supplies: 2
PS Status: 1 working
Max No. of Fans: 3
Fan Status: 3 working
CPU Temperature (C): 59
CPU Temperature Threshold (C): Warning 90;
Faulty 100
CPU Temperature Status: OK
On-board Temperature (C): 33
On-board Temperature Threshold (C): Warning 60;
Faulty 70
On-board Temperature Status OK
You can change the default temperature scale to Fahrenheit using the CLI
command device set –temperature_units f.