SANRAD I3.1.1205 Switch User Manual


 
4-12 SANRAD V-Switch CLI User Manual
Table 4-2: V Switch Interfaces
Type Name Description Alias Phys Address
RS232 cons RS232 Management
Int
cons 000000000000
ETHERNET mgnt Fast Ethernet
Manage
mgnt 000000000000
FibreChannel fc1 FC MMF fc1 000000000000
FibreChannel fc2 FC MMF fc2 000000000000
SCSI SCSI1 SCSI Ultra 3 SCSI1 000000000000
SCSI SCSI2 SCSI Ultra 3 SCSI2 000000000000
ETHERNET eth1 Gigabit Ethernet
Net
eth1 00081a000110
ETHERNET eth2 Gigabit Ethernet
Net
eth2 00081a000111
ETHERNET eth3 Gigabit Ethernet
Net
eth3 00081a000112
Viewing SCSI Storage Ports and Bus IDs
Use the CLI command pscsi show to view all SCSI storage ports and their
corresponding SCSI bus ID.
pscsi show
Alias BusID
pscsi3 12
pscsi4 7
Setting a SCSI Storage Port Bus ID
Each storage port connected to a SCSI device must have a SCSI bus ID. Use the
CLI command pscsi set busid to set a storage port’s SCSI bus ID.
pscsi set busid
You need to define two parameters to set a storage port SCSI bus ID:
SWITCH PARAMETER DEFINITION STATUS EXAMPLE
-if
INTERFACE STORAGE PORT
NUMBER
MANDATORY
pscsi3
-id
IDENTITY SCSI BUS IDENTITY OPTIONAL
DEFAULT: 7
12