Tektronix 3000 Switch User Manual


 
2-70
Section 2 — Startup & Configuration
Operating the Model 3000 With Kaleidoscope
After the Model 3000 has been connected to a Kaleidoscope DPM
(Digital Picture Manipulator), as described in the Installation
section of the Model 3000 Installation & Service manual, and after
the Model 3000 has been properly configured, as described earlier
in this section, all that is required for the two devices to operate
together is to enable both of them.
With both ends of the 3000/Kaleidoscope interface enabled,
communication is established which provides E-MEM recall and
run control.
To Enable the Model 3000
1. Turn on (high tally) the DPM button that was configured for
Kaleidoscope (usually DPM 1) on the E-MEM Enables
subpanel.
2. Bring up the DPM Setup Menu on the Model 3000 as follows:
a. Press CONFG on the main menu panel.
b. Select EXTERN I/F> in the Configuration Menu.
c. Select DPM I/F> in the External Interface Menu.
3. Set the DPM TYPE in the 3000 DPM Setup Menu to KSCOPE.
To Enable Kaleidoscope
1. Press the Kaleidoscope Top Menu RESRCES button.
2. Select USER PREFS in the Resources Menu.
3. Select EXTRN CNTRL in the User Preferences Menu.
4. Select ENABLE 3/4000 in the External Control Menu.