Texas Instruments TMS320C64x DSP Network Card User Manual


 
Video Capture Registers
Video Capture Port3-60 SPRU629
3.13.4 Video Capture Channel x Field 1 Stop Register (VCASTOP1, VCBSTOP1)
The video capture channel x field 1 stop register (VCASTOP1, VCBSTOP1)
defines the end of the field 1-captured image or the end of the raw data or TSI
packet. VCxSTOP1 is shown in Figure 332 and described in Table 317.
In raw capture mode, the horizontal and vertical counters are combined into
a single counter that keeps track of the total number of samples received.
In TSI capture mode, the horizontal and vertical counters are combined into
a single data counter that keeps track of the total number of bytes received.
The capture starts when a SYNC byte is detected. The data counter counts
bytes as they are received. The FRMC bit (in VCxSTAT) gets set each time a
packet has been received.
Figure 332. Video Capture Channel x Field 1 Stop Register (VCASTOP1, VCBSTOP1)
31 28 27 16
Reserved
VCYSTOP
R-0 R/W-0
15 12 11 0
Reserved
VCXSTOP
R-0 R/W-0
Legend: R = Read only; R/W = Read/Write; -n = value after reset
Table 317. Video Capture Channel x Field 1 Stop Register (VCxSTOP1) Field Descriptions
Description
Bit field
symval
Value BT.656 or Y/C Mode Raw Data Mode TSI Mode
3128 Reserved 0 Reserved. The reserved bit location is always read as 0. A
value written to this field has no effect.
2716 VCYSTOP OF(value) 0FFFh Last captured line. Upper 12 bits of the
data size (in data
samples).
Upper 12 bits of
the data size (in
data samples).
1512 Reserved 0 Reserved. The reserved bit location is always read as 0. A
value written to this field has no effect.
110 VCXSTOP OF(value) 0FFFh Last captured pixel
(VCXSTOP 1).
Must be an even
value (the LSB is
treated as 0).
Lower 12 bits of the
data size (in data
samples).
Lower 12 bits of
the data size (in
data samples).
For CSL implementation, use the notation VP_VCxSTOP1_field_symval