Toshiba A10 Personal Computer User Manual


 
4.18 Fluorescent Lamp 4 Replacement Procedures
4.18.1
Replacing the TMD 14.1 Inch XGA Fluorescent Lamp
Replace the Toshiba 14.1-inch XGA fluorescent lamp according to the following procedures
and Figures 4-45 to 4-56.
4.18.1.1 Disassembling Fluorescent Lamp
Peeling off the tapes and insulation sheets
1. Flip the module over and place it on a flat surface that is free of foreign objects.
2. In the order (1), (2), and (3) shown in Figure 4-45, remove the tape for fixing the FL
tube cable, two pieces of tape on the bezel that are close to the FL tube, and the X-
PCB insulation sheet.
CAUTION: (1) Be careful not to damage the TAB.
(2) Leave the insulation sheet on the bezel to allow the reuse of the sheet.
F9402
製品ラベル
>PC-GF1 3<
BL S/N ラベル
FL破棄ラベル
CAUTIONラベル
3
22
1
Product label
CAUTION label
BL S/N label
Label (cautions for disposal of FL tubes)
Figure 4-45 Replacing 14 Inch TMD fluorescent lamp (1)