Toshiba A10 Personal Computer User Manual


 
4.18 Fluorescent Lamp 4 Replacement Procedures
4
4.18.12 Replacing the 15.0 Inch SXGA+ Sharp Fluorescent Lamp
CAUTION: When you replace the fluorescent lamp, wear finger covers or gloves to avoid
contaminating or damaging the LCD module. Be careful not to let dust or other foreign
substances into the LCD module.
Disassembling the 15.0-inch SXGA+ Sharp Fluorescent Lamp
To disassemble the 15.0 inch SXGA+ Sharp fluorescent lamp, follow the steps below and
refer to Figures 4-153 to 4-162.
1. Turn the LCD module face down, and remove the protection cover S (A), protection
cover G (B), fixing tape (C) and fixing tape for lead wire (C).
NOTE: 1) Be careful not to damage the TCP or chips.
2) Discard the tapes removed. Do not reuse them.
(
A
) Protection cover S
(C) Fixing tape
(B) Protection cover (G)
(C) Fixing tape for lead wire
Figure 4-153 Replacing 15.0 Inch Sharp fluorescent lamp (SXGA+) (1)
Satellite A10/TECRA A1/Satellite Pro A10 Maintenance Manual (960-445) 4-145