3Com 4500 Switch User Manual


 
2-9
<Sysname> system-view
# Enter AUX user interface view.
[Sysname] user-interface aux 0
# Specify to authenticate users logging in through the console port using the local password.
[Sysname-ui-aux0] authentication-mode password
# Set the local password to 123456 (in plain text).
[Sysname-ui-aux0] set authentication password simple 123456
# Specify commands of level 2 are available to users logging in to the AUX user interface.
[Sysname-ui-aux0] user privilege level 2
# Set the baud rate of the console port to 19,200 bps.
[Sysname-ui-aux0] speed 19200
# Set the maximum number of lines the screen can contain to 30.
[Sysname-ui-aux0] screen-length 30
# Set the maximum number of commands the history command buffer can store to 20.
[Sysname-ui-aux0] history-command max-size 20
# Set the timeout time of the AUX user interface to 6 minutes.
[Sysname-ui-aux0] idle-timeout 6
After the above configuration, you need to modify the configuration of the terminal emulation utility
running on the PC accordingly in the dialog box shown in
Figure 2-4 to log in to the switch successfully.
Console Port Login Configuration with Authentication Mode Being
Scheme
Configuration Procedure
Follow these steps to configure console port login with the authentication mode being scheme:
To do… Use the command… Remarks
Enter system view
system-view
Enter AUX user interface view user-interface aux 0
Configure to authenticate
users in the scheme mode
authentication-mode
scheme [ command-
authorization ]
Required
The specified AAA scheme
determines what authentication
mode is adopted, local or
RADIUS.
By default, users logging in
through the console port (AUX
user interface) are not
authenticated.
Quit to system view
quit