Command Reference Guide E1 Interface Configuration Command Set
61200510L1-35E Copyright © 2005 ADTRAN 604
remote-loopback
Use the remote-loopback command to configure the interface to respond to loopbacks initiated by a
remote unit (or the service provider). Use the no form of this command to disable this feature.
Syntax Description
No subcommands.
Default Values
By default, all interfaces respond to remote loopbacks.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 1.1 Command was introduced.
Functional Notes
This controls the acceptance of any remote loopback requests. When enabled, remote loopbacks are
detected and cause a loopback to be applied. When disabled, remote loopbacks are ignored.
Usage Examples
The following example enables remote loopbacks on the E1 interface:
(config)#interface e1 1/1
(config-e1 1/1)#remote-loopback