Command Reference Guide ATM Sub-Interface Config Command Set
61200510L1-35E Copyright © 2005 ADTRAN 727
dial-backup auto-restore
Use the dial-backup auto-restore command to configure the sub-interface to automatically discontinue
dial backup when all network conditions are operational. Use the no form of this command to disable the
auto-restore feature.
Syntax Description
No subcommands.
Default Values
By default, all backup endpoints will automatically restore the primary connection when the failure
condition clears.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, and 4000 Series units.
Command History
Release 1.1 Command was introduced.
Release 8.1 ATM sub-interface was added.
Usage Examples
The following configures the AOS to automatically restore the primary connection when the failure
condition clears:
(config)#interface atm 1.1
(config-atm 1.1)#dial-backup auto-restore