Avaya P880 Switch User Manual


 
Cajun P550/P880/P882 Switch User Guide
Configuring System Information
3-9
Setting One-
Time Summer
Time Hours
You can set one-time summer time hours using either the web agent
or the CLI.
Setting One-Time Summer Time Hours Using the Web
Agent
To set Summer Time Hours that are not based on a standard rule
using the web agent:
1. Select System Clock from the System> Configuration group
on the web agent window. The System Clock dialog box
opens (Figure3-4).
2. Select Summer Time Hours Algorithm from the Clock
Options field. The Summer Time Hours Configuration
window opens (Figure3-5).
3. Select Enable from the Enable State pull-down menu. The
default is Disable.
4. Enter the reset value for the clock in minutes in the Offset
field. For example, if you intend to reset the clock forward or
backward by one hour, keep the default value of 60 minutes.
5. Select the check box next to the One-Time field to set the date
and time for Summer Time Hours on a one-time basis:
a. Enter the specific Month, Day, and Year when the Summer
Time Hours start and end.
b. Enter the Hour and Minutes when the Summer Time
Hours start and end.
6. Click APPLY to save your changes, or CANCEL to clear your
selection.