LED-PRO • User’s Guide 147
_K==oÉãçíÉ=`çåíêçä=mêçíçÅçä
LED-PRO Remote Commands
ldj=ãçÇÉ
• Description: Set LED Wall Output Gamma.
• Parameters: mode [0-3], Indoor1 | Indoor2 | Outdoor1 | Outdoor2
• Query:
OGM?
Returns the Output Gamma value in the format
= mode
S OGM 1 (Set Output Gamma to Indoor1)
S OGM? (Queries Output Gamma)
le^qs=åååå
• Description: Set Output Horizontal Active. The minimum and maximum limit is
dependent on the output resolution.
• Parameters: nnnn - Output Horizontal Active: nnnn[ (Actual Output H Active * 2/
10, with absolute minimum value of 150) - +(Actual Output H Active * 6/5, with
absolute maximum of Output H Total - Output H Sync)]
• Query:
OHATV?
Returns the Output Horizontal Active value in the format
= nnnn
S OHATV 1024 (Set Output Horizontal Active to 1024)
S OHATV? (Queries Output Horizontal Active)
lemlp=åååå
• Description: Set Output Horizontal Position. The minimum and maximum limit is
dependent on the output resolution.
• Parameters: nnnn - Output Horizontal Position: nnnn[(Output H Sync) - +(Output
H Active )]
• Query:
OHPOS?
Returns the Output Horizontal Position value in the format
= nnnn
S OHPOS 296 (Set Output Horizontal Position to 296)
S OHPOS? (Queries Output Horizontal Position)
lepvk`=åååå
• Description: Set Output Horizontal Sync Width. The minimum limit is 4 and
maximum limit is dependent on the output resolution.
Note
Command is only applicable when LED Wall Ctrl = Local.