Barco LED-PRO Projector User Manual


 
LED-PRO • User’s Guide 45
4. Operation
Using the Setup Menu
pÜ~êéåÉëë
From the Analog Source Alignment Menu, select Sharpness to adjust the sharpness of
the selected input. This selection sets the scaler's sharpening (or softening) value.
The sharpening range extends from -10 (softest) to +10 (sharpest).
0 is the default setting (which sets the scaler to its optimum sharpness).
`äáé=íç=pìÄ_äâ
From the Analog Source Alignment Menu, select Clip to SubBlk to eliminate low level
noise in black regions of the image.
The adjustment range is 0 to -15.
0 is the default setting.
iìã~=qê~ÅâáåÖ
From the Analog Source Alignment Menu, select Luma Tracking to prevent green haze
from appearing in regions of low light.
The adjustment range is 0 to -15.
0 is the default setting.
bafa=asf
From the Analog Source Alignment Menu, select EDID DVI to display the EDID DVI In
Format Menu, which enables you to update LED-PRO's preferred EDID resolution. Refer
to the “Programming EDID
” section on page 53 for instructions.