Canon FY8-13EX-000 Copier User Manual


 
2. Cleaning the Cleaning Pad and the Primary Corona Roller
1) Detach the primary corona unit.
2) Place the primary corona assembly as shown in the figure, and clean the cleaning
pad e with a cotton wad r or folded lint-free paper.
Caution:
Dry-wipe only. Do not use water, alcohol, or solvent.
Be sure to use strokes in one direction only.
Figure 4-321
3) Clean the primary charging roller t with lint-free paper y while rotating it.
Caution:
Dry-wipe only. Do not use water, alcohol, or solvent.
Be sure to use strokes in one direction only.
Figure 4-322
COPYRIGHT
©
1997 CANON INC. CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)