Canon FY8-13EX-000 Copier User Manual


 
Table 10-19-3
10-111
COPYRIGHT
©
1997 CANON INC. CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 10 TROUBLESHOOTING
Code Cause
• Lens cable (displacement, tear)
• Lens home position sensor
(PS2; faulty)
• Slide shutter (operation)
• Blank shutter home position
sensor (PS3; faulty)
• Change solenoid (SL1; faulty)
• Lens motor (M3; faulty)
• DC controller (faulty)
• Scanning lamp (faulty)
• Composite power supply
(faulty)
• DC controller (faulty)
• DC controller (faulty)
• Composite power supply
(faulty)
• Power supply frequency
(fluctuation)
• Composite power supply
(faulty)
• DC controller (faulty)
• DC controller (faulty)
• DC controller (faulty)
• DF controller (faulty)
• Connector (poor contact)
• DC controller (faulty)
• The Remote Diagnostic
Device II controller (faulty)
• Communication (with the
Remote Diagnostic Device II)
Description
• The lens home position sensor signal
(LHP) is not generated within a specific
period of time after the power switch has
been turned on.
• The lens home position signal (LHP) is
generated longer than a specific period of
time.
• The blank shutter home position signal
(BSHP) is not generated when the slide
shutter is moving.
• The lamp is identified as being on during
standby.
• The lamp is identified as being off during
copying operation.
A communication error is detected between
the CPU (Q301) on the DC controller and the
CPU (Q512) on the composite power supply.
The intervals of the zero cross signal is
outside the tolerance.
The IPC (Q104) cannot be initialized at
power-on.
An IPC communication error has been
detected twice within 1 sec.
An error in communication with the DF
cannot be cleared.
• A communication with the Remote
Diagnostic Device II has been
successfully but failed in the middle.
• An open circuit is detected on the line with
the Remote Diagnostic Device II.
E210
E220
E717
E240
E261
E711
E712
E710