2. Adjusting the Mirror Position (optical distance between No. 1 mirror and No.
2/No. 3 mirror)
1) Keep the mirror positioning tool handy.
(See “4 Assembling the Mirror Positioning Tool on P. 10-17.”)
2) Move the No. 1 mirror mount forward, and match the long hole in the front side plate
and the cable fixing screw q.
Figure 10-213
3) Loosen the set screw on the pulley.
4) Set the mirror positioning tool w to the No. 1 mirror mount and the No. 2 mirror mount
(both front and rear).
Figure 10-214
5) Attach the scanner cable fixing to the No. 1 mirror mount using two screws e (both
front and rear).
Figure 10-215
10-16
CHAPTER 10 TROUBLESHOOTING
COPYRIGHT
©
1997 CANON INC. CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
q
(front) (rear)
(front)
Mirror positioning tool (front) Mirror positioning tool (rear)
(front)
w
e
(front) (rear)