3) Remove the two screws e, and detach the separation pad unit r.
Figure 5-712
6. Adjusting the Left/Right Registration
Make adjustments so that the position of the image is as shown in Figure 5-714 when
the Test Sheet is copied in Direct.
a. Pick-Up from the Cassette
Turn the screw q shown in Figure 5-713 to adjust the position of the cassette hook
plate.
standard: 0 ±1.5 mm
clockwise turn: moves the paper in the direction of – shown in Figure 5-714
counterclockwise turn: moves the paper in the direction of + shown in Figure 5-714
Figure 5-713 Figure 5-714
COPYRIGHT
©
1997 CANON INC. CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 5 PICK-UP/FEEDING SYSTEM
5-22
(-) (+)
0±1.5mm
0
2
4
6
8
10
q