Canon FY8-13EX-000 Copier User Manual


 
CHAPTER 8 INSTALLATION
COPYRIGHT
©
1997 CANON INC. CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
8-1
I. SELECTING THE SITE
Keep the following in mind when selecting the site of installation; if possible, pay a
visit to the user’s before the delivery of the machine.
1. The site must provide a power outlet that may be used exclusively for the machine
and that meets the rating ±10%.
2. The site must be 7.5°C/45.5°F to 30°C/86.0°F in temperature and 10% RH to 80%
RH in humidity. In particular, avoid areas near water faucets, boilers, humidifiers, or
refrigerators.
3. Avoid areas near sources of fire, areas subject to dust or ammonium gas, or areas
exposed to the direct rays of the sun; if necessary, provide curtains to shut out the
sun.
4. The site must be well ventilated.
5. Make sure that the floor will remain in contact with the copier’s feet and will keep the
copier level.
6. Make sure that there will be work space that meets the measurements shown in
Figure 8-101; in other words, there must be distances A and B around the copier
when measured with its front door open.
Figure 8-101
B
AA
A
A: 50cm/
B: 10cm/
19.7in
3.9in