Citizen CL-S703 Label Maker User Manual


 
Chapter 3 Disassembly and Maintenance
3-6. Adjustments
CL-S700/CL-S703/CL-S700R 3-44
(2-1) Init Fix-Thru sensitivity adjustment
Init Fix-Thru sensor is the transparent sensor (fixed type), i.e. “SA, Sensor U” (Fixed type).
Preparation:
1. Prepare recommended media or media to be used.
2. Peel off labels from the liner.
3. Open the head block and the sensor arm, and then set the media.
4. Be sure that the media is put on the “SA, Sensor Bottom” (Fixed type). If the media
has black mark, avoid that area.
5. Close the sensor arm and the head block.
Procedure:
1. Enter Factory/Service mode by turning on the power while pressing and holding the
[MENU], [FEED] and [STOP] keys.
“Factory Setup” main menu appears.
2. In “Factory Setup” main menu, press the [STOP] (X) key to enter Factory Setup mode.
The first submenu “Sens Vol Adj.” appears.
3. Press the [MENU] (T) key until “Init Fix-Thru” submenu appears.
4. Press the [STOP] (X) key to enter Init Fix-Thru sensitivity adjustment mode.
5. Press the [MENU] (T) key to select “Exec”.
6. Press the [STOP] (X) key to execute adjustment.
Adjustment starts and the following screen is display. (Media is not fed.)
W
X
Init Fix-Thru
No
Exit
Enter
S
T
W
X
Init Fix-Thru
Exec
Exit
Enter
S
T
W
X
Now !!
Executing
Exit
Enter
S
T
W
X
Factory Setup
Init Fix-Thru
Exit
Enter
S
T