Chapter 3 Disassembly and Maintenance
3-6. Adjustments
CL-S700/CL-S703/CL-S700R 3-48
(2-3) Init Adj-Thru sensitivity adjustment
Init Adj-Thru sensor is the transparent sensor (adjustable type), i.e. “SA, Sensor U”
(Adjustable type).
Preparation:
1. Prepare recommended media or media to be used.
2. Peel off labels from the liner.
3. Open the head block and the sensor arm, and then set the media.
4. Be sure that the media is put on the “SA, Sensor Bottom” (Adjustable type). If the
media has black mark, avoid that area.
5. Close the sensor arm and the head block.
Procedure:
1. Enter Factory/Service mode by turning on the power while pressing and holding the
[MENU], [FEED] and [STOP] keys.
“Factory Setup” main menu appears.
2. In “Factory Setup” main menu, press the [STOP] (X) key to enter Factory Setup mode.
The first submenu “Sens Vol Adj.” appears.
3. Press the [MENU] (T) key until “Init Adj-Thru” submenu appears.
4. Press the [STOP] (X) key to enter Init Adj-Thru sensitivity adjustment mode.
5. Press the [MENU] (T) key to select “Exec”.
6. Press the [STOP] (X) key to execute adjustment.
Adjustment starts and the following screen is display. (Media is not fed.)
W
X
Init Adj-Thru
No
Exit
Enter
S
T
W
X
Init Adj-Thru
Exec
Exit
Enter
S
T
W
X
Now !!
Executing
Exit
Enter
S
T
W
X
Factory Setup
Init Adj-Thru
Exit
Enter
S
T